37TM

Three-Phase
Static Energy Meter 37TM

Designed to meter high value residential and commercial segment of energy consumers in three-phase distribution network and for net-metering in solar roof-top installations with remote communication option.
  • Home
  • Static Energy Meter 37 TM

Three-Phase
Static Energy Meter 37TM

Designed to meter high value residential and commercial segment of energy consumers in three-phase distribution network and for net-metering in solar roof-top installations with remote communication option.
  • Home
  • Static Energy Meter 37 TM

Three-Phase Static Energy Meter 37TM

  • VISIONTEK 37TM Three Phase Electronic Energy Meter is designed to meter residential and commercial category consumers in distribution networks. The meter is targeted at the deregulated energy markets which require flexible tariff structures and a modern energy management. 37TM is a perfect combination of well-proven metering technology sealed in a single enclosure with multiple communication interface options.  The intelligent features of detecting and recording different anomaly conditions and cover opening events make it ideal choice for revenue protection for distribution companies. 37TM Energy Meter complies with IS-13779, CBIP-325 and communication protocol in accordance with IS 15959 (Part -1) with the latest amendments as Category C2 for interoperability in data transfer from the meter.

    • Class 1.0 accuracy compliance with IS/IEC standards
    • LCD for display of measured parameters & for anomaly conditions
    • LED indications for calibration of active energy & reactive energy
    • Billing point registers storage up to last 12 months
    • Programmable TOU / TOD
    • Event logging of anomaly conditions and cover open detection
    • Ultrasonic welding option
    • Programmable load profile for 15 or 30 or 60 minutes
    • Interval for kWh, kVArh, kVAh, Voltages, Currents
    • Optical communication port / IR* for local meter reading
    • RS 232 port*, Inbuilt LPRF module* for Remote Meter reading
    • Meter reading in absence of mains with built-in battery
    • High immunity to magnetic influence and electrostatic discharge
    • Sealing provision for meter cover & base and terminal cover
    • Connection Type: Three Phase Four Wire
    • Accuracy Class: 1.0 as per IS-13779, IEC 62052-11/IEC 62053-21, CBIP TR 88 / 304
    • Voltage Nominal : 33 x 240V (L - N) Operating : -40 % to +20 %
    • Current: 10-60A, 5-30A*, 10-40A*, 20-100A*
    • Power Factor Range: Zero lag – Unity – Zero lead
    • Frequency : 50 Hz ± 5%
    • Starting Current: 0.2% of Ib at Vref
    • UPF Power Consumption Voltage Circuit : Voltage Circuit: 1.5W/8.0VA | Current Circuit: 4.0VA
    • Display : LCD with backlit, 8 digit 7 segment display for parameters & icons for anomaly conditions
    • Real Time Clock: ± 3 min per year
    • Communication Interfaces: Optical port Hardware compatible to IEC62056-21
      •  > IR port
      •  > RS 232 port (RJ 11)
      •  > Inbuilt LPRF module
      •  > BLE Communication
      •  > Communication protocol as per IS 15959 Part-1 Category C2
    • Data Storage: Non-volatile memory with a retention time of minimum 10 years
    • Measured Values/Units: Active Energy
      •  > Reactive energy
      •  > Apparent energy
      •  > Maximum Demand kW/Rising Demand
      •  > Maximum Demand kVA/Rising Demand
      •  > Instantaneous Phase wise Voltages
      •  > Instantaneous Phase wise Currents
      •  > Instantaneous Frequency
      •  > Instantaneous Power Factor
    • Maximum Demand (MD) Register: Register Programmable Integration period for 15 or 30 or 60 minutes Sliding window or Fixed window method
    • Billing registers: Up to last 12 months bill point registers
    • Time of Use / Time of Day: Programmable time zones
    • Tariff registers: Programmable tariff registers
    • Events Logging: Missing Potential
      •  > Potential Unbalance
      •  > High Potential
      •  > Low Potential
      •  > Current Reversal
      •  > Current Circuit High
      •  > Current Circuit Low
      •  > Current Unbalance
      •  > Current Circuit open
      •  > Current Circuit short (bypass)
      •  > CNeutral Disturbance
      •  > Power ON / OFF
      •  > Top Cover Open Detection
      •  > Magnetic Influence
      •  > Low Power Factor
    • Temperature Range: -10° to 60° C
    • Humidity: ≤95%
    • Enclosure : IP 51
    • Dimensions (L x W x H) in mm: 232 x 192 x 96 (varies with terminal-cover length)
    • Weight: 1.35 Kg ± 100 gms

Customized Solutions That Fit All Critical Industry & Manufacturing Needs!

Building relationships and projects that last, serving an impressive list of clients with experience in multiple industries.

Request A Quote

Interested in cooperation or have questions? Just fill out the form and we will call you back. Or you can call us and we will provide the necessary help!

    Customized solutions that fit all critical industry & manufacturing needs!

    Building relationships and projects that last, serving an impressive list of clients in multiple industries.

    Get in Touch with Us

      OUR CLIENTS

      Trusted by leading companies
      across diverse sectors